FUJI FKB Remote seal type pressure transmitter (DC4~20mA+HART protocol)
FUJI FDB Remote seal type pressure transmitter(FOUNDA TION Fieldbus protocol or PROFIBUS-PA)
1.Product Introduce
The Fuji FKB Remote Seal flange pressure transmitter is an extension and development of the Fuji pressure transmitter technology. It is used to measure liquid, gas or steam liquid levels, flow, and pressure, and then transform it into a 4-20madc signal output.
The transmitter utilizes a unique micromachined capacitance silicon sensor with advanced floating capsule structure and new micro-processing technology, the transmitter has high accuracy, good stability, safety and reliability, and easy to use.
FCX-AIII series transmitters with safety funtion have obtained the certificate of SIL certification by TÜV.
2.Products Features:
FUJI FKB Remote Seal Type Flange Pressure Transmitter is suite for Measure the level, pressure and density of high temperature, high viscosity, easy crystallization, easy precipitation, and strong corrosion.
FKB Flange Remote Pressure Transmitter oftenly use in below area:
1. Visual medium at high temperature;
2. The medium that is easy to crystal;
3. Settled medium with solid particles or suspension;
4. Corrosion or toxic medium;
5. It can eliminate the occurrence of the surrounding environment phenomenon that leaks the pressure of the pressure tube; when the isolated solution is used, the tedious work of the isolation solution is required due to the instability of the measurement signal;
6. Continuous accurate measurement interface and density;
7. Far -pass device can avoid the intercourse of different instantaneous media, so that the measurement results truly reflect the actual situation of the process change;
8. Hygiene cleaning requirements are very high;
9. In the production of food, beverages and pharmaceutical industries, not only requires the transmitter contact medium to meet sanitary standards, but also facilitates rinse to prevent cross -pollution from different batch media.
3.Products Specification:
Measured fluid: Liquid,Gas,or vapour
Range, operating pressure, and overrange limit:
Output signal: (1)FKB: DC4~20mA+HART protocol
(2)FDB: FOUNDA TION Fieldbus protocol or PROFIBUS-PA
Power Supply: General DC10.5 ~ 45V
Intrinsic safety DC10.5 ~ 26V
With arrestor DC10.5 ~ 32V
4: Parameter table
Diaphragm Materials: SUS316L,Tantallum, monel,Hastelloy-C,316L SS Gold-plated, Zirconium,Titanium
Accuracy ranting:( For spans greater than1/10 of URL ±0.1% or ±0.2%,high accuracy(Optional) ±0.065%
Output signal/ Power supply: DC4-20mA/DC10.5~45V(Non-Explosion)
Promote/inhibit: -100%~+100%URL
Containment structure: JIS C0920 Immersion type(Equivalent IEC IP67,NEMA6/6P
Explosion-approvals :NEPSI, FM, ATEX, IECEx, CSA, TIIS
Ambient temperature: Sensor unit: -40~350˚C / Electronics: -40~85˚C
Process connection : Individual flange rating
5:CE Approved
6:Products Explosion Proof
Ordering information
1. Model code
2. Span
3. Please select the direction of output (Notuse/OVER/UNDER) when the transmitter is fault (Burnout). If unspecified, it is Notuse.
4. Please select the output mode (linear or square root). If unspecified, it is linear mode.
5. If the scale of indicator is selected to actual scale (9th code: D,H,P,S), please select the items of display (digit, scale, unit , etc).
6. Please select the tag plate according to need.(up to 14 digit, consist of lettters and numbers).