has excellent bubble resistance and is suitable for small converters used in mechanical devices. It can measure the liquid flow rate from the piping diameter of φ25 to φ1200mm.
It is not necessary to open the cover of the converter, and the operation can be set from the front
PC loader software comes standard
Model Converter FSV Detector FSS
Applicable pipe diameter Inner diameter 25~225mm (detector: FSSA)
Inner diameter 50~1200mm (detector: FSSC)
Piping material Plastic (PVC, PVDF, PP, etc.), metal
Measuring range 0~±0.3 ????? ±10m/s
Accuracy ±1.5% of rate or ±1.0% of rate (when the flow velocity is more than 2m/s)
Response speed 0.2s (in high-speed response mode)
fluid temperature
-20~+100℃(Detector FSSA)
-40~+120℃(Detector FSSC)
Ambient temperature -20~+50℃ (inverter), -20~+60????80℃ (depending on the detector)
Analog output DC4 ~ 20mA, 1 point (load resistance: maximum 600Ω)
Contact output Open collector output: 2 points, accumulation, alarm, etc.
1P/day~100P/s (open collector)
Serial transmission RS-485/MODBUS (option)
Display LCD (2 lines, 16 bit) with backlight
Keyboard 4 keys (Esc, Up, Shift, Enter)
Power supply voltage AC100~240V, 50/60Hz or DC20~30V
Converter housing model Aluminum alloy, IP65
Inverter installation method Wall mount or pipe mount
Inverter Dimensions H140×W137×D68mm(IP65)