Current location:Home > Technical Articles >

Technical Articles

475 Hart communicator set fuji transmitter parameter

Time2023-06-07 11:21 linkS:
  475 hand operator is an indispensable helper in industrial production, especially in the setting of the fuji transmitter. When it turns on, it will automatically poll the online device at address 0, and the handset will display a "connection error" message when no device is connected. Opening the handset after a device has been connected displays the online menu for that device. From the online menu you can press the left arrow key to return to the main menu.

1. Main menu:
 
475 hand operator main menu mainly includes fuji temperature transmitter, fuji pressure transmitter, general menu three functions, you can return to the main menu by pressing the left arrow key several times.

2. fuji Pressure transmitter:
 
By connecting the HART protocol device to the 475 hand operator, we can access the fuji pressure transmitter unit through the main menu.

3. Read process variables:
 
Select the first item in the fuji pressure transmitter to enter the function of reading process variables. The process variables listed in this menu include principal variables, output current and percentage values, etc., and are updated in real time with each communication.

4. Diagnostics/Services
 
Select the second item in the fuji pressure transmitter to access the Diagnostic/Service menu, 475 manual operator This menu includes equipment self-test, loop current detection and instrument calibration options. Select the device self-test to realize the device self-test and report the test results. Choosing loop current detection can make the fuji transmitter output a current signal, which is convenient to verify whether the whole loop is normal.

5. Basic Settings
 
Select the third item in the fuji pressure transmitter to access the Basic Settings menu, which allows you to make changes to some common information.

6. Set details
 
In the fuji pressure transmitter, select the fourth item to enter the detailed Settings menu, which provides more configuration information, and the detailed Settings vary greatly for different HART devices.

475 manual operator depending on the connected device, its online menu may also be different, fuji pressure transmitter detailed description see the appendix. The 475 Hand operator provides a common interface when operating unregistered devices. This interface can complete the common functions of all HART communication devices.

Copyright © 2022 Xian Tosi Da Technology Co., Ltd Record No:

On-line-chat Tel QR code

Tel

029-83460512 / 15349231350

Sweep and pay attention to us