Simple description:Yokogawa ADMAG SF Series Magnetic Flowmeter Yokogawa SF flowmeter Yokogawa Flowmeter GENERAL DESCRIPTION The ADMAG SF is the Standard and Friendly magnetic fl owmeter which Secures your profi tability and Facilitates your productivity. The...

Details
Yokogawa ADMAG SF Series Magnetic Flowmeter
Yokogawa SF flowmeter
Yokogawa Flowmeter


  • GENERAL DESCRIPTION
The ADMAG SF is the Standard and Friendly magnetic fl owmeter which Secures your profi tability and Facilitates your productivity.
The ADMAG SF is ideal for general application like utilities for various industries.
Although the ADMAG SF is for general use, the ADMAG SF inherits extremely reliable electrode structure and lining based on years of experience and achievement of ADMAG series.
With outstanding reliability and ease of operation and maintenance, the ADMAG SF will contribute reducing total cost of ownership by properly selecting products
including ADMAG TI series.
• Size: 15 to 300 mm (0.5 to 12 in.)
• Lining: Fluorocarbon PFA, PTFE
• Process connection: GB, ASME, EN

  • FEATURES
  •  Standard Reliable Sensor Structure and Stable Measurement
Electrode and lining (PFA and PTFE) structure of sensor is very reliable by the same design based on fi eld proven technology of ADMAG Series. This reliable sensor achieves stable fl ow-measurement.
  • Flexible Electrical Connection Direction
The transmitter or the terminal box can be rotated arbitrarily to change the directions of electrical connection on the site.
  • Friendly Operation with Versatile Display
Wizard of Easy setup, operation authority level setting for ensuring safety, display backlight fl ashing (Squawk) function are available with display unit.This display unit display Chinese to support your easy operation.
  • Communication Protocol
HART, BRAIN
  • GENERAL
Measuring Principle:
By applying the occurrence of electromotive force proportional to the flow velocity when fluid moves in the magnetic field, the flowmeter can measure the flow velocity of conductive liquid. It calculates the instantaneous flow rate, integrated flow rate, etc. from the measured flow velocity.
System Configuration:
Basic configuration: Sensor, Transmitter, Cable

  Function
Snesor Detects the flow velocity
Transmitter Amplifies a sensor and converts signals.
Cable(*) Signal cable (for flow signal), excitation cable (for coil excitation)
* :  Necessary for Remote type with construction
separated to a sensor and a transmitter.
The excitation cable is to be supplied by customer.
Main Element of Sensor:

  Function
Wetted Part Lining, Electrodes, Grounding Devices (*).
Non-wetted Part Flanges, Housing, Excitation coil,Measuring pipe
*: grounding ring plate, grounding ring electrode.
Note: Grounding devices are for taking the reference electric potential from the process fluid in measuring the electromotive force, and are fixed at two locations, upstream and downstream  of the flow. They are unnecessary when the reference potential is taken from installed piping. For details of grounding, read "Cautions on Selection and Installation".
Main Element of Transmitter:
Display unit, Setting keys, Amplifier unit (including
I/Os and power supply unit)

  • CONSTRUCTION
Use:
Use Specification
General-
purpose
Non explosion protection for the use in non-hazardous area. Applicable to Integral Flowmeter, Remote Sensor, or Remote
Transmitter. IP Protection Grade: IP66/IP67
Explosion
Protection
Explosion protection for the use in hazardous area. Applicable to Integral Flowmeter, Remote Sensor, or Remote Transmitter.
IP Protection Grade: Read "Explosion Protection".
Construction:
Two types of Integral and Remote type.

Type Construction
Integral type Integrated structure of a sensor and a transmitter.
Remote type Separated structure of a sensor and a transmitter, which are connected by a signal cable and an excitation cable (*).
* :  To be supplied by customer.
Combinable Transmitter: SF14A
Note:  When changing the combined transmitter, readjustment of the meter factor by actual flow calibration is necessary to ensure accuracy.
Maximum Cable Length: 100 m (328 ft) for SF14A remote transmitter
Process Connection:
Wafer, flange type are available. For the availability of lining and size range, read "MODEL AND SUFFIX CODE".

Type Process connection
Wafer GB PN16, PN40 ASME Class 150, Class 300 EN PN16, PN40
Flange GB PN10, PN16, PN40 ASME Class 150, Class 300 EN PN10, PN16, PN40
Electrode Construction:
PFA Lining External insertion type
PTFE Lining Internal insertion type
Grounding Device Construction:
Grounding Ring Plate Ring flat plate with mounting bracket
Grounding Ring Electrode Electrode is inserted into ring-shaped short pipe with PFA lining, with mounting bracket

Wetted Part:
Wetted Part Material
Lining Fluorocarbon PFA, Fluorocarbon PTFE
Electrode Stainless steel 316L, Nickel alloy (*),Tantalum, Titanium               * : ASTM B574 UNS N10276 or ASME SB-574 UNS N10276
Grounding Device Grounding Ring Plate Stainless steel 316L, Nickel alloy (*),Titanium
* : ASTM B575 UNS N10276 or ASME SB-575 UNS N10276
Grounding Ring Electrode :Tantalum
Gasket (Note) PFA Lining
Standard: None (not necessary) Optional (for plastic piping):
GA: Fluororubber
GC: Acid-resistant fluororubber
GD: Alkali-resistant fluororubber
PTFE Lining
Standard:
Not necessary for sizes 125 mm (5 in.), or should be supplied by
customer.
Necessary for sizes 150 mm (6 in.) and above and should be supplied by customer.
For metal piping, PTFE-sheathed gasket is recommended.
Optional (for plastic piping):
GA: Fluororubber
GC: Acid-resistant fluororubber
GD: Alkali-resistant fluororubber
Installed Pipe
Standard:
None (supplied by customer)
Optional (for wafer type, with bolts,
nuts, and gaskets):
BSC: Chloroprene rubber (CR)
BSF: PTFE-sheathed non-asbestos joint sheet
Note: The description is about the material of gaskets supplied with flowmeter, to be used between the sensor pipe and grounding ring or the process flange.
This includes whether gaskets are necessary, or whether gaskets should be supplied by customer.For details of gaskets, read "Cautions on Selection and Installation" and "Optional Code".

  • Cable Entry:
JIS G1/2 female
ASME 1/2 NPT female
ISO M20 x 1.5 female
Cable Entry Direction:
For Integral Flowmeter and Remote Sensor, the cable entry direction can be specified from +90, +180, or -90 degree rotation when optional code RH is ordering, and also can be changed by customer after delivery. However, it can not be changed after delivery when optional code DHC (district heating and cooling / condensation proof use) is selected.

  • Mounting:
Remote Transmitter: 2-inch pipe mounting
  • Grounding:
Grounding Resistance: 10 Ω or less
Note: When the built-in lightning protector as standard is not required, grounding resistance 100 Ω or less can be applied.
For grounding of explosion protection, appropriate construction is required according to the regulations of each country.

  • Communication Function:
HART Communication:
Protocol Version: HART 7
Communication Signal:
Superimposed on the Current Output 1
Communication Line Condition:
Load Resistance:
230 to 600 Ω (including cable resistance)
BRAIN Communication:
Communication Signal:
Superimposed on the Current Output 1 Communication Line Condition:
Load Resistance:
250 to 450 Ω (including cable resistance)
Load Capacitance: 0.22 μF or less
Load Inductance: 3.3 mH or less
Input Impedance of Communicating Device:
10 kΩ or more (at 2.4 kHz)
Communication Distance:
Up to 1.5 km (0.93 miles), when polyethylene insulated PVC-sheathed cables (CEV cables)
are used. Communication distance varies depending on the type of cable and wiring used.
Distance from Power Line:
15 cm (6 in.) or more. (Parallel wiring should be avoided)

  • Output Function:
Output Signal
Current Output (Active)
4 to 20 mA DC signal
Load Resistance: 750 Ω maximum, including cable resistance
Pulse/Status Output (Passive)
Transistor contact output (open collector) Contact Capacity: 30 V DC (OFF), 200 mA (ON)
Pulse Rate:
0.0001 to 10000 pps (pulse per second)
Pulse Width:
0.05, 0.1, 0.5, 1, 20, 33, 50, 100, 200, 330, 500, 1000, 2000 ms or Duty cycle 50% configurable Frequency Output Range: 1 to 12500 Hz

Order datasheet,pls feel free to contact us by email sales6@xatzd.com


 


Reuqust

留言框

  • Products:

  • Message:

  • Company:

  • Name:

  • Tel:

  • E-mail:

  • Address:

Previous:Yokogawa DY025 Vortex Flow Meter

Next:none


Recommend

Copyright © 2022 Xian Tosi Da Technology Co., Ltd Record No:

On-line-chat Tel QR code

Tel

029-83460512 / 15349231350

Sweep and pay attention to us