FUJI FKX Small flange Remote seal type differential pressure Transmitter (Flow)
FUJI FDX Small flange Remote seal type differential pressure Transmitter(Flow)
1.Product Introduce
FCX-AIII series intelligent flange remote type transmitter is an expanded variety on the basis of FCX-AⅡ series differential pressure and pressure transmitter, that is, on the basis of pressure and differential pressure varieties, the pressure and The capillary tube filled with silicone oil transmits the pressure, which solves the problem that the conventional transmitter cannot measure the pressure signal at a long distance under the special process conditions on site (high viscosity of medium, strong corrosiveness, high temperature).
FCX-AIII series intelligent flange remote transmitter mainly solves the remote transmission measurement of pressure signal and the realization of accuracy index, temperature index and static pressure index
2:Fuji FKX Flange transmitter Features
a:It can be directly connected to 1 1 /2 inch, 2 inch flange. The
transmitter can be mounted on the 1 1 /2B, 2B pipe without the
reducer union.
b:It's applicable for flow measuring instrument without guide
pipe.There're models connected with 1 /2B, 3 /4B flange, so the
measuring instrument system can be constructed without guide
pipe. It sovles the problem of pipe blockage, leakage, corrosion
and so on. Also it can be connected to the following Process
Connection:
· Thread connetion Rc 1 /2, Rc 3 /4, 1 /2-14NPT, 3 /4-14NPT
c: Excellent environmental adaptaboility
The advanced floating cell protects sensor from temperature,
static pressure and overpressure effect, and controls the
total measurement error of the filed to the minimun.
d: Excellent operability and easy to use
It has an excellent operability and easy to use in any application.
Small and portable remote flange (Flange
specification 1 1 /2 inch, weight approx. 2.9 kg)
5-digit digital indiactor
· Stainless steel AMP case
·Built-in RFI filter and lightning arrester
· Various anti-corrosive materials
· Built-in local configurator with 3 push buttons
· Products used for high temperature and high vacuum
e: The transmitter can communicate using FUJI, HART,
communication protocol, and also can use FOUNDATION
FIELDBUS or PROFIBUS protocol after changing circuit.
3:Measured fluid: Liquid,Gas,or vapour
Range, operating pressure, and overrange limit:
Output signal: (1)FKX: DC4~20mA+HART protocol
(2)FDX: FOUNDA TION Fieldbus protocol or PROFIBUS-PA
Power Supply: General DC10.5 ~ 45V
Intrinsic safety DC10.5 ~ 26V
With arrestor DC10.5 ~ 32V
4: Parameter table
Diaphragm Materials |
SUS316L,Tantallum, monel,Hastelloy-C,316L SS Gold-plated, Zirconium,Titanium |
Accuracy ranting |
( For spans greater than1/10 of URL ±0.1% or ±0.2%,high accuracy(Optional) ±0.065% |
Output signal/ Power supply |
DC4-20mA/DC10.5~45V(Non-Explosion) |
Promote/inhibit |
-100%~+100%URL |
Containment structure |
JIS C0920 Immersion type(Equivalent IEC IP67,NEMA6/6P |
Explosion-approvals |
NEPSI, FM, ATEX, IECEx, CSA, TIIS |
Ambient temperature |
Sensor unit: -40~350˚C / Electronics: -40~85˚C |
Process connection |
Individual flange rating
|
5: CE Certificate
Ordering information
1. Model code
2. Span
3. Please select the direction of output (Notuse/OVER/UNDER)
when the transmitter is fault (Burnout). If unspecified, it is Notuse.
5. If the scale of indicator is selected to actual scale (9th code:
D,H,P,S), please select the items of display (digit, scale, unit , etc).
6. Please select the tag plate according to need.(up to 14
digit, consist of lettters and numbers).
4. Please select the output mode (linear or square root). If