Current location:Home > Technical Articles >

Technical Articles

Discontinued Fuji FHC Replaced by Fuji FKC transmitter

Time2022-04-06 14:48 linkS:
  The model FHC difference pressure transmitter is discontinued on Mar,09,The newest replacement modle is FUJI FKC DP Transmitter version 5.
Below is main difference between FHC & FKC difference Transmitter:

  Fuji FHC difference transmitter feature Fuji FKC difference transmitter feature
communications protocol Hart DC4~20mA+HART FOUNDATION Fieldbus and PROFIBUS
Accuracy:  ±0.1% ±0.065%
Measuring Range: 1.06…500Kpa 0.1…2000Kpa
Diaphragm & wetted material 316L stainless steel SUS316L, Hastelloy-C, SUS316L Gold-plated, Monel, Tantalum,
Explosion proof FM,CSA,TIIS, TIIS,FM,ATEX,IECEx,CSA,NEPSI
Response Time Code “3”0.3s,
Code “5” and “6”  0.2s
FKC □11/ FDC□11 ….0.33s
FKC□22/FDC□22…..0.3s
FKC □□3/FDC□□3…..0.12s
FKC□□5        0.08s
FDC□□9        0.08s
 
In view of above parameter,the FCX III series transmitter is upgrade Fuji model,we would like workout a new FKC model basic of FHC old model,for example:

Old Discontinued Model: FHCB 33V4 PACYYAA



New Replacement model: FKCT-33V5-PACYY-BAY






 

Copyright © 2022 Xian Tosi Da Technology Co., Ltd Record No:

On-line-chat Tel QR code

Tel

029-83460512 / 15349231350

Sweep and pay attention to us