Current location:Home > Technical Articles >

Technical Articles

Fuji ZKM type in-line zirconia oxygen analyzer

Time2022-03-04 14:23 linkS:
  Fuji ZFK8, ZKM type in-line zirconia oxygen analyzer

--------
A high-speed response oxygen analyzer that does not require sampling equipment. It is most suitable for combustion management of boilers and various industrial furnaces.



Features:
 
Zirconia sensor can be replaced and maintenance is simple.
 
The fast response speed of 4~7 seconds can be used for combustion control.
 
Two types of enclosures IP66 and IP67 are provided for different usage environments.
 
It has the function of aging diagnosis and regeneration of sensor electrodes, which prolongs the service life and improves the reliability.
 
The setting operation can be performed easily without opening the case. (When using ZKM1 case)
 
Various diagnostics and protection functions are designed for safety considerations.

Main Specifications:


 
Comprehensive Specifications
Item Specification
Measurement object Oxygen in non-flammable gases
measurement method In-line Zirconia Type
Measuring range 0~2・・・・・50 vol % O2  (Can be set arbitrarily within the range)
Repeatability ±0.5% FS
linear ±2% FS
Zero point and full scale drift ±1% FS/Week
Response time 4~7S(Via the calibration gas inlet)
Analog signal output DC4~20mA or DC0~1V,insulation
voltage AC100V~120Vor AC200V~240V
 
Detector Specifications
Item Specification
measure gas temperature  -10~+600℃(duct type)
 -10 ~ +1500℃(ejector)
measure gas pressure -3~+3 kPa
filter Alumina, Quartz filter paper
structure IP66 (except front-end filter)
Weight Estimate 1.6kg(except duct)
 
Converter Specifications
Item Spefication
Measured concentration value display Digital 4-digit display with backlight
Contact output Relay contact 6 points
Contact input No-voltage contact 3 points
Communication function RS-232C(Standard)or RS-485(Option)
Others function Thermocouple disconnection detection, keyboard lock
Output hold function During calibration, during purging, the output is maintained
Optional function Combustion efficiency display, purging, automatic correction, switching cock
structure IP66 or IP67(as specified)
 
Duct Specification
Item Specification
Type General Type, Corrosion Resistant Type, Purge Nozzle Type, High Dust Type
Length 300mm ~ 1000mm(as specified)
mounting flange JIS5K 65A(High dust type is  80A)


There are also many others zirconia oxygen analyzer avaliable, if you need ,pls send us your request by below informations:

Xi'an Tosi Da Technology Co., Ltd

Address: RM11710,building3,ZhuQue,Street,YanTa,District,Xi'An City,China.
 
Tel:029-83460512/15349231350
 
E-Mail:Sales6@xatzd.com 
Website:www.fujitransmitter.com

Copyright © 2022 Xian Tosi Da Technology Co., Ltd Record No:

On-line-chat Tel QR code

Tel

029-83460512 / 15349231350

Sweep and pay attention to us