  • Price:

Simple description:YB-88G basic oxygen analyzer Model: YB-88G Purpose: To measure the oxygen concentration in flue gas or non-combustible gas. Scope of application: online monitoring of oxygen content in flue gas generated during combustion of boilers, kilns,...

Details
YB-88G basic oxygen analyzer

Model: YB-88G
 
Purpose: To measure the oxygen concentration in flue gas or non-combustible gas.
 
Scope of application: online monitoring of oxygen content in flue gas generated during combustion of boilers, kilns, heating furnaces and other combustion equipment; oxygen content detection in inert gas; pollution control of medical waste incinerators; CEMS supporting control of pollution emissions ; Steel refining furnace VOD application.
 
Main feature:
 
        1. Long service life: The oxygen sensor adopts coating technology, which has strong anti-corrosion ability of flue gas; the lead wire adopts double wire, which overcomes the shortcomings of the pressure-contact lead wire and can double the life of the oxygen detector.
 
        2. In-line type: The contact part between the oxygen detector and the flue gas adopts a new type of high-temperature alloy steel, and the oxygen detector can be directly inserted into the flue at temperatures below 700°C, making the measurement more accurate and the response time faster.
 
        3. Wide applicable temperature range: when the flue gas temperature is low (<750°C), the oxygen sensor can be heated to 750°C for constant temperature operation; when the flue gas temperature is high (>750°C), it can run at floating temperature according to the actual flue gas temperature.
 
        4. Strong anti-interference ability: The converter circuit adopts a fully floating structure, which has strong anti-interference ability, making the measurement data reliable and accurate.
 
Technical Specifications:
 
   1. Measuring range: 0~20.60%O2; can be set within the range of 0~100%O2.
 
       2. Basic error: <±2% of full scale
 
       3. Repeatability: <±0.5% of full scale
 
       4. Stability: <±1% of full scale (24 hours)
 
       5. Response time: 90% of the oxygen response is reached within 5 seconds from the start of the standard gas.
 
       6. Current output: 4~20mA, load resistance ≤500Ω, isolated.
 
       7. Power supply voltage: 220±10%VAC.
 
       8. Power consumption: less than 150W
 
       9. Detector insertion length: 180mm, 400mm, 600mm, 800mm, 1000mm, 1200mm, 1500mm. Special size can be customized.
 
     10. Ambient temperature: detector -10~80℃; converter -10~45℃. 

 


Reuqust

留言框

  • Products:

  • Message:

  • Company:

  • Name:

  • Tel:

  • E-mail:

  • Address:


Recommend

Copyright © 2022 Xian Tosi Da Technology Co., Ltd Record No:

On-line-chat Tel QR code

Tel

029-83460512 / 15349231350

Sweep and pay attention to us